10G SFP+ or 10GBASE-T for 10GbE Network?

In order to cater for the increasing need for speed and bandwidth in telecommunication networks, high speed Ethernet has never stopped developing, from earlier 100M, 1G, 10G, to 40G and 100G. The standard for 10 Gigabit Ethernet (IEEE802.3ae) was ratified in 2002. Many subscribers find it difficult to make a choice between fiber and copper. This article will introduce the media options for 10GbE network and make a comparison between them.

Media Options for 10GbE Network
  • 10G SFP+ Modules
    SFP+ module supports both fiber optic cables and DAC (direct attach cable). It delivers a wide variety of 10GbE Ethernet connectivity options for data center, enterprise wiring closet, and service provider transport applications. But it has the limitations that will prevent the media from moving to every server.
  • SFP+ Direct Attach Cable
    SFP+ cable is designed for 10GbE access layer interconnection in data center. It includes direct attach copper cables and active optical cables. DAC is a lower cost alternative to fiber, but it can support limited transmission distance and it’s not backward-compatible with existing GbE switches. DAC requires the purchase of an adapter card and requires a new top of rack (ToR) switch topology. DAC is more expensive than structured copper channels, and cannot be field terminated.
  • 10GBASE-T SFP
    10GBase-T SFP enables 10GbE connections with unshielded or shielded twisted pair cables over distances up to 100 meters. 10GBase-T technology appears as SFP is not compatible with twisted pair cabling system typically used in data centers. With 10GBase-T SFP, the migration from 1GbE to 10GbE can be easily achieved.
Comparison of 10G SFP+ and 10GBase-T SFP

Latency
Low latency becomes so important since the adoption of private cloud applications increases. It’s beneficial for ensuring fast response time and reducing CPU (center processing units) idle cycles so that improve data center efficiency.As to 10GBASE-T SFP, the physical connection (PHY) standard uses block encoding to transport data across the cable without errors. The block encoding requires a block of data to be read into the transmitter PHY, a mathematical function run on the data before the encoded data are sent over the link. It happens the same on the receiver side. This standard specifies 2.6 microseconds for the transmit-receive pair, and the block size requires latency to be less than 2 microseconds. While 10G SFP+ applies simplified electronics without encoding, and common latency is around 300 nanoseconds per link.

You may think that two microseconds are not high. But what if a TOR infrastructure where traffic is passing 4 hops to reach the destination? 10.4-microsecond delay will be caused when using 10GBASE-T SFP. The following table tells details about the latency of SFP+ cable, 10G SFP+ (eg. Finisar FTLX1471D3BCV) and 10GABSE-T SFP for different number of links.

Number of Links SFP+ Cable Latency 10G SFP Latency 10GBASE-T SFP Latency
1 0.3 0.1 2.6
2 0.6 0.2 5.2
3 0.9 0.3 7.8
4 1.2 0.4 10.4
5 1.5 0.5 13.0
6 1.8 0.6 15.6

From the above table, it shows that the latency of 10GBASE-T SFP is the highest. As network links grow, the latency turns to be higher. It’s known that the lower latency, the faster the network speed. High latency in the data center infrastructure results in delays in CPU and application works, therefore limiting data center efficiency and increasing operational costs.

Power Consumption
Power consumption is also one of the important factors to be considered in data centers. Engineers are sensitive to power consumption and find a way to seek the lowest possible power consumption technologies. It’s said that every watt of power consumed, typically two additional watts are needed for cooling.10GBase-T components today require anywhere from 2 to 5 watts per port at each end of the cable depending on the distance of the cable. But 10G SFP+ requires about 0.7 watt regardless of distance. The figure below compares the power consumption of three media options of 10GbE Ethernet.

Conclusion

Lower power consumption and lower latency makes 10G SFP+ well suited for large high-speed supercomputing applications where latency is a critical factor and where high port counts can add up to significant power savings.